Physical & Environmental

Physical / Operational

  • Case color: Black
  • Dimensions: 3.6” (90 mm) High × 4.7” (119 mm) Wide × 4.8” (123 mm) Deep
  • Weight: 1.04 lbs (580 g)
  • Input Power Range 10 – 30 VDC, reverse polarity protected (external fuse recommended)
  • Power Consumption (no load): < 1 A
  • Power Consumption (max load): < 1.5 A

Panel Mount Info

  • Bolt Pattern: Identical to EMM620 Panel Meter – see Mounting Pattern Drawing for details.
  • Mounting Kit Accessories: Pan head Phillips screws (for various panel thicknesses) – 6/32 x 1/2″ (4), 6/32 x 5/8″ (4), 6/32 x 3/4″ (4)

Environmental

  • Operating Temperature Range:  -40F to +158F (-40°C to +70°C)
  • Storage Temperature Range: -40F to +176F (-40°C to +80°C)
  • Relative Humidity: 0 to 95%, non-condensing
  • Vibration: 4.4G, 3 axis, frequency swept 5-2000 Hz
  • Emissions Compliance: FCC part 15 Class A, Industry Canada
  • NEMA4 weatherproof panel-mount design
  • Class I Div. 2 (CSA/UL) Hazardous Location Compliance

Operational Specs

Protocols

  • Modbus ASCII, RTU, TCP
  • J1939

Communication Interfaces

  • RS-232, RS-485
  • Ethernet

Current Loop Inputs

2 Dedicated 16-bit, 4-20 mA

  • Isolation: 500 Volts
  • High frequency analog filtering

Analog Outputs

2 14-bit linear (isolated) analog outputs

  • 4-20 mA up to 33 V max., or output for PID control

2 14-bit voltage outputs

  • 0 – 10 V with 100Ω output impedance
  • Maximum current of 10 mA

2 Frequency outputs

  • 0.00 Hz – 6250 Hz

Multipurpose I/O

6 Multipurpose I/O, configured as DI, DO,or VI

  • Digital Inputs:
    • 0-30 VDC
    • Configurable pull-up
    • Adjustable threshold voltage
  • Digital Outputs:
    • 0-30 VDC
    • Configurable pullup
    • Open collector
    • Output rating – 70mA max (hold), 140mA trip 1A peak, 50Ω impedance
  • Voltage Inputs:
    • 12bit with full scale 0 – 25 VDC
    • 100kΩ impedance

Hardware Counters

  • 2Tachometers, 80,000 Counts/second
  • 3Counters, 300,000 Counts/second
    • Configurable as 2 quadrature encoders

RTD Sensor Channel

116-bit (non-isolated) RTD

  • Pt 100 or 500 Ω DIN, IEC
  • Measurement range: -328°F to +1562°F (-200 to +850 °C)

Modbus

  • Modbus Slave communications over RS-232/485
  • Supports Modbus RTU and Modbus ASCII protocols
  • Support for Function Codes 2 & 4
  • User configurable register mapping for all Process & Control Process data
  • Includes preassigned registers for J1939 SPN & DTC data

Data Logging

  • 450 MB data storage, > 14 million data points
  • Selectively log process, control, I/O, J1939 data
  • Configurable sampling period: 1 second to 24 hours
  • Auto file/log creation on power up or config. change
  • User configurable sequence names
  • Export data to USB (CSV format)
  • User configurable export – complete data sequence or time interval subset
  • Overwrite (looping) feature for continuous logging
  • J1939 diagnostic trouble codes stored separately

J1939

  • 16 selectable J1939 parameter display screens
  • Support DM1 active diagnostic codes
  • Support for PGN requests
  • Support VIN requests
  • ISOBUS support
  • Ability to disable transmit
  • Fixed and arbitrary addressable

User-Configurable

  • Inputs mapped to outputs
  • Control Loops: PID, signal conversion/ retransmission
  • Threshold triggers, latching or momentary
  • Direct output control from touchscreen